Stage Dimensions:

Draperies and Masking:

Dressing Rooms:

Lighting System:

  1. Power source is located DR, approximately 10' (3m) from proscenium arch. Company Connection/Road Show Power availability is two-200amp VAC fused disconnect switches, 3-phase 120/208 volt, 4-wire fed from one 400amp breaker, which also feeds the house light dimmers. (325 is available for company use when house lights are used.) This power supply can be used in addition to or separately from stage lighting system. Rated cold-water ground is adjacent to company connection. NO COMPANY PLUG IS AVAILABLE! Connection must be via hard-wired connectors to company's distribution box. Connection must be made by a University-certified electrician. A University electrician must make the connection, remain on site during all use, and disconnect.
  2. Control board, ETC 48/96, located in the rear of the balcony
  3. Patch control is computerized. Headset stations are available.
  4. All lighting positions require adapter from Twistlock to 2-pin and Ground 20 amp connectors. 
  5. All electric trusses have two schedule 80 pipes. Instruments can be double hung (above and below the wireway) if desired.
  6. Balcony rail lighting is approximately 60' (20m) from the plaster line. A single circuit feeds six (6) PAR 56 units (Dimmer 13), used as curtain warmers.
  7. Ceiling ports, approximate 40' (13m) from plaster line, Dimmers 1 through 11.
  8. First Electric: 3' 8" (1.2m) upstage of plaster line. 9 twenty amp circuits on 1'6" (.5m) centers. Can be flown to floor. Dimmers 16 through 18 and 20-25.
  9. Second Electric: 10' 6" (3.6m) upstage of plaster line. 9 twenty amp circuits. Can be flown to floor. Dimmers 26 through 34.
  10. Third Electric: 21' 3" (7m) upstage of plaster line. 3 twenty amp circuits. Can be flown to floor. Dimmers 35 through 37.
  11. Fourth Electric: 29' (9.5m) upstage of plaster line. 5 twenty amp circuits. Prehung with four Altman three-bay cyc strips. Dimmers 38 thorugh 42.
  12. Floor pockets: Three positions on each side, under 1st, 2nd and 3rd electrics, paired circuits in each pocket. Dimmers 44 through 46 plus 48.
  13. Eight pipes (trees) available for sidelighting on stage. No boxbooms or diagonals in house.

GEL:

The Kenan Auditorium does not supply color media. Being a state agency in a town with no theatrical supply house, purchasing and receiving color media requires an average of three weeks.

COMMUNICATIONS:

Seven (7) ClearCom belt packs are available. Telephones are located SR, SL, and in the control booth. 

PIANO:

Steinway D Concert Grand

AUDIO EQUIPMENT:

FLY LINE POSITIONS:

  1. Grand Drape
  2. Border/teaser
  3. 1st Electric
  4. open
  5. Projection Screen (cannot be moved)
  6. open
  7. Border/teaser
  8. open
  9. 2nd Electric
  10. Border/teaser
  11. Mid-stage traveler
  12. open
  13. Border/teaser
  14. open
  15. 3rd Electric
  16. Open
  17. 4th Electric
  18. open
  19. Rear Traveler
  20. Cyc

Please note that they are sets of DEAD HUNG LEGS between linesets 15-16, and 16-17, and a dead hung border between linesets 15-16.

AUDITORIUM SEATING:

Orchestra capacity: 728, including 11 removable seats for wheel chair accommodations and 10 ADA-approved slide in seats.

Balcony capacity: 286. (Balcony is not wheel chair accessible)

Click to link to SEATING CHART